Sign In | Join Free | My wneducation.com
China DONGGUAN YUYANG INSTRUMENT CO., LTD logo
DONGGUAN YUYANG INSTRUMENT CO., LTD
Verified Supplier

8 Years

Home > Fire Testing Equipment >

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998

DONGGUAN YUYANG INSTRUMENT CO., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998

Brand Name : YUYANG

Model Number : YYF089

Certification : GB 19083-2010 ,YY 0469-2011,GB 2626-2006,BS EN136-1998

Place of Origin : China

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union

Supply Ability : 300/sets/Month

Delivery Time : 8-10 days

Packaging Details : Plywood box

Linear velocity of head automatic movement : (60±5)mm/s

Metal head mold surface thickness : 2~3mm,Resistance to flame combustion

Combustion timer : 0~9999.9s

Accuracy : ±0.1s

Power supply : AC220V,50Hz,500W

Weight : About 30kg

Contact Now

BS EN136-1998 Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃

Description:

The Flammability test procedure evaluates the flammability of medical textiles including face masks, surgical gowns, and drapes. The test method is designed to comply with 16 CFR Part 1610. This test is required by the ASTM F2100 (Standard Specification for Performance of Materials Used in Medical Face Masks) to ensure that all face masks meet the requirements for Class 1 flammability. Testing is also required for 510(k) submissions to the FDA. In addition to the Flammability test, Nelson Labs can perform all ASTM F2100 testing.

Standard: GB 19083-2010 medical protective mask technical requirements

Scope:

It is the special test equipment mainly used for testing medical masks flame retardant properties.

Instrument Description:

The device is a mask with a head mold at a certain line speed after contact with the flame, then test the burning performance on masks.

Main feature:

1, PLC + touch screen control system; make test more convenient operating, visualization;

2, mask fixture for the metal body head mold, can fully simulate the actual use of the state mask.

3, the burner height can be adjustable

4, automatic timing positioning made by the burner

5, burning time, fire-retardant time are automatically recorded, show the figures.

6, with a flame temperature measurement probe, flame temperature display.

7, automatic control system, automatic ignition;

8, the burner with propane (liquefied gas) and other combustible gas interface.

9, automatic timing, automatic storage of test data; easy access to experimental reports

Specifications:

1, head mold automatic movement line with the speed of (60 ± 5) mm / s

2, the height of the flame can be adjusted to 40 ± 4mm

3, with a flame temperature measurement detection thermocouple

4, the flame from the top of the burner height is(20 ± 2) mm, the temperature is (800 ± 50) ℃

5. The distance between the top of the burner and the lowest point of the mask is (20 ± 2) mm

6, the burner height adjustment range of 30mm

7, metal head mold wall thickness of 2 ~ 3mm, resistant to flame burning

8, continued burning time and smoldering time timer: 0 ~ 9999.9 seconds, accuracy: ± 0.1 seconds

9, the power supply: AC220V, 50Hz, 50W

10, Weight: about 30kg

Temperature (800 ± 50) ℃

Burner Height Adjustment Range

30mm
Metal Head Mold Wall Thickness 2 ~ 3mm
Time timer 0 ~ 9999.9S
Accuracy ± 0.1
Weight About 30kg

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998


Product Tags:

smoke density test apparatus

      

fire test chamber

      
Buy cheap Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998 product

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN YUYANG INSTRUMENT CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)